Insulation resistance test of transformer is divided into three parts.

Insulation resistance test standard for transformer.

With a little record keeping and common sense however you can get a good picture of the insulation condition from values that are only relative. This test can be repeated during the service life of the transformer and verified against the result obtained during manufacturing as a check to determine if the insulation is malfunctioning or decaying. Use the megger test at a low voltage side. The transformer neutral bushing is to be disconnected from earth during the test.

Adjust megger tester at 1000 v dc. Insulation resistance decreases in temperature or moisture. Isolation required for the test. Apply the test voltage and note the reading.

Value at 60 seconds after application of the test voltage is referred to as the insulation resistance of the transformer at the test temperature. The transformer neutral bushing is to be disconnected from earth during the test. Clean the terminals of the transformer. Ansi neta mts 2015 table 100 11 insulation resistance test values rotating machinery for one minute at 40 c.

The test is performed with a power factor test kit and the connections are the same as for the megger test the insulation resistance test. Values based on ieee std 43 2013. Value at 60 seconds after application of the test voltage is referred to as the insulation resistance of the transformer at the test temperature. Leakage current should be as small as possible therby ir value should be as high as possible r v i.

The megger insulation tester is a small portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. A rated line to line voltage for three phase ac machines line to ground voltage for single phase machines and rated direct voltage for dc machines or field windings. Insulation resistance is the ratio of the applied voltage dc to the total leakage current. Measure insulation resistance between low voltage windings and the main body of the transformer.

Steps of this test.

Surge Arresters Selection Application And Testing Overview

Surge Arresters Selection Application And Testing Overview

Understanding Insulation Resistance Testing Ec M

Understanding Insulation Resistance Testing Ec M

Insulation Resistance Testing Measuring Monitoring Technical Article

Insulation Resistance Testing Measuring Monitoring Technical Article

Electrical Knowledge Center T D 11 Measurement Of Insulation Resistance Ir Part 2

Electrical Knowledge Center T D 11 Measurement Of Insulation Resistance Ir Part 2